| Availability: | |
|---|---|
| Quantity: | |
KL-003
FSKEJU
KL-003
The FSKEJU KL-003 dental examination lamp is a 12-LED lighting unit designed for dental chair and treatment-room applications. It provides adjustable illumination from 8,000 to 30,000 lux and combines white and yellow light settings to support different chairside lighting requirements.
With a rated power of 20W and AC 12–24V input, the KL-003 is designed as a dental equipment lighting component rather than a general-purpose room light. Its specified light field measures 80 × 160 mm at a working distance of 700 mm.
Additional examination and operating lights can be reviewed in our Dental Light range.
KL-003 Product Snapshot
Model: KL-003
Product Type: Dental Examination Lamp
Light Source: 12 LEDs
Power: 20W
Illuminance: 8,000–30,000 lux
White Light: 4800–5500K
Yellow Light: 4000K
Input Voltage: AC 12–24V
Dental treatment lighting should provide a defined working field that can be positioned over the oral treatment area while fitting into the overall dental-chair workflow. The KL-003 is designed for this type of chairside application and can be used for dental treatment units, equipment replacement and treatment-room lighting projects.
When selecting a dental examination lamp, illuminance, color temperature, light-field size, working distance, electrical requirements and mounting compatibility should be evaluated together rather than comparing only the number of LED elements.
The KL-003 provides an illumination range of 8,000 to 30,000 lux, allowing the light level to be adjusted for different chairside lighting requirements.
For clinic and dental equipment projects, the specified illuminance range provides a measurable reference for comparing the KL-003 with the lighting requirements of the intended treatment environment.
Key Lighting Range
8,000–30,000 lux adjustable illuminance range for the KL-003 dental examination lamp.
The KL-003 provides two color-temperature settings. The white-light setting operates at 4800–5500K, while the yellow-light setting operates at 4000K.
These defined color-temperature options allow the lighting configuration to be selected according to the clinic's working preferences and treatment-room requirements.
Lighting Mode | Color Temperature | Selection Note |
|---|---|---|
White Light | 4800–5500K | Suitable when a higher color-temperature working light is preferred. |
Yellow Light | 4000K | Provides an alternative lower color-temperature lighting option. |
The KL-003 provides an 80 × 160 mm light spot at a distance of 700 mm. This provides a measurable reference for evaluating the illuminated area at the stated working distance.
Working distance and light-field dimensions are relevant when integrating a dental lamp with a treatment chair because lamp-arm position, patient-chair height and operator access influence where the lamp head can be positioned during treatment.
The KL-003 has a rated power of 20W and an input voltage of AC 12–24V. These electrical specifications should be checked against the dental unit or installation system before the lamp is connected.
For replacement projects, visual similarity between two lamp heads does not confirm electrical compatibility. Input voltage, wiring, connectors and mounting arrangements should all be reviewed before replacing an existing dental operating light.
Electrical Compatibility Note
The KL-003 requires AC 12–24V input. Check the electrical output and connection arrangement of the intended dental unit before installation. Lamp compatibility should not be determined from mounting appearance alone.
KL-003 Dental Examination Lamp Specifications | |
|---|---|
Model | KL-003 |
Product Type | LED dental examination lamp |
LED Configuration | 12 LEDs |
Illuminance | 8,000–30,000 lux |
White Color Temperature | 4800–5500K |
Yellow Color Temperature | 4000K |
Rated Power | 20W |
Input Voltage | AC 12–24V |
Spot Size | 80 × 160 mm at 700 mm distance |
Brand | FSKEJU |
Mounting Configuration | Available upon request |
Control Method | Available upon request |
When the KL-003 is being considered as a replacement dental lamp, electrical and mechanical compatibility should be reviewed before ordering. A lamp with similar dimensions or appearance may still use a different voltage, mounting interface or connector arrangement.
✓ Dental unit model: provide the manufacturer and model number whenever available.
✓ Existing lamp photos: provide clear images of the lamp head, mounting connection and wiring.
✓ Input voltage: check compatibility with the KL-003 AC 12–24V requirement.
✓ Mounting interface: compare the existing lamp-arm and lamp-head connection.
✓ Control requirement: specify the required brightness and color-temperature controls.
✓ Required quantity: indicate whether the requirement is for individual replacement, clinic installation or distributor supply.
Our dental light range includes several models for different dental chair and treatment-room requirements. Individual model numbers should be compared according to their lighting specifications, control functions and installation requirements rather than treated as interchangeable lamp heads.
Model | Product Type | Key Configuration |
|---|---|---|
KL-002 | Dental Surgical Lamp | 8-LED bi-color configuration |
KL-003 | Dental Examination Lamp | 12 LEDs, 8,000–30,000 lux and white/yellow color-temperature settings |
KL-004 | Dental Chair Oral Light | 12-LED configuration with sensor technology |
If your project requires a specific lighting function or mounting arrangement, compare the technical specifications and installation requirements of the individual model before selection.
The KL-003 is used within the dental treatment environment and should be included in the clinic's regular equipment cleaning and inspection procedure.
The lamp head, control area and other frequently contacted surfaces should be cleaned according to the applicable product instructions. Cleaning agents should be compatible with the supplied plastics, coatings and optical components.
Avoid applying abrasive materials or unsuitable chemicals to the optical area, as residue or surface damage can affect the condition of the light-emitting surface.
The KL-003 provides defined specifications for illuminance, color temperature, voltage, power and light-field size. For complete installation planning, mounting, control and connection requirements should also be reviewed before ordering.
✓ Required quantity and destination: provide these details for quotation and shipment planning.
✓ Mounting method: review compatibility with the intended dental unit or lamp arm.
✓ Control functions: specify the required brightness and color-temperature control functions.
✓ Handle configuration: request the applicable handle information if this is important to your installation or cleaning procedure.
✓ Packing data: request carton dimensions and gross weight when planning international shipment.
Founded in 2009 in Foshan, Guangdong, FOSHAN KEJU MEDICAL APPARATUS CO., LTD. designs, develops, manufactures and supplies dental equipment for clinics, distributors and equipment projects.
Our dental light range includes examination, surgical and dental-chair lighting products for different equipment configurations. We can assist with model selection based on lighting specifications, electrical requirements, mounting compatibility and treatment-unit configuration.
Review additional products in our Dental Light category or learn more about our company and manufacturing background on the FSKEJU About page.
KL-003 is a 12-LED dental examination lamp designed for dental chair and treatment-room lighting applications.
The KL-003 provides an adjustable illuminance range of 8,000–30,000 lux.
The KL-003 provides a white-light setting of 4800–5500K and a yellow-light setting of 4000K.
The KL-003 requires AC 12–24V input and has a rated power of 20W. Electrical compatibility should be checked before installation.
The KL-003 provides an 80 × 160 mm light spot at a working distance of 700 mm.
Sensor control is not included in the KL-003 specifications shown here. If sensor-operated lighting is required, please contact our team to review the appropriate dental light configuration.
No. Compatibility depends on input voltage, mounting interface, electrical connection and control arrangement. These requirements should be compared with the existing dental unit before replacement.
Request KL-003 Specifications and Quotation
Provide your required quantity, destination market and dental unit or mounting information. Our team can then review the appropriate KL-003 configuration, installation requirements and quotation with you.
Color temperature: | White:4800 -5500K Yellow : 4000K |
Power: | 20W |
Input voltage: | AC12-24V |
illuminance: | 8000-30000LUX |
Spot size: | 80X160mm ( distance:700mm ) |
Standardize your dental unit instrument tray to improve ergonomics, speed, and infection control.
Stop dental unit cross-contamination with anti-retraction valves. Learn how air water controls protect patients and ensure CDC compliance.
Dental chair drift ruins precision. Learn why electromechanical lifting systems are essential for stable, ergonomic dentistry.
Dental chair ambidexterity can expand scheduling but often leads to wobbly systems. Learn the 60-second rule, hidden plumbing, and ergonomic checks.
Avoid costly downtime and tool damage from improper dental air compressor sizing. Learn the exact CFM formula and sizing strategy for any clinic.